View cart “Chauvin Arnoux : C.A 832 Sound Level Meter” has been added to your cart.

TSI Airflow Instruments : TA440 Velocity Meter

RM8,890.00


Multiple meters for the price of one, yet they are simple to operate.

Download PDF

Availability: in stock

Items are currently out of stock. Will ship in 12-14 weeks.

CompareCompare

Additional Features and Benefits
+ Simultaneously measures temperature and velocity
+ Displays up to three measurements simultaneously
+ Calculates volumetric flow, and actual/standard velocity
+ Articulated probe versions available
+ Data logging and LogDat2ā„¢ downloading software included
+ Measures humidity (TA440), wet bulb, and dewpoint temperature

Applications
+ HVAC system performance
+ Commissioning
+ Plant maintenance
+ Critical environment certification
+ Duct traverses “

There are no reviews yet.

Be the first to review “TSI Airflow Instruments : TA440 Velocity Meter”

    Ask a question about this product

    Questions and answers of the customers

    There are no questions yet, be the first to ask something for this product.

    Velocity
    Range (TA410): 0 to 20 m/s (0 to 4,000 ft/min)
    Range (TA430, TA440): 0 to 30 m/s (0 to 6,000 ft/min)
    Accuracy (TA410)Ā¹&Ā²: Ā±5% of reading or Ā±0.025 m/s (Ā±5 ft/min), whichever is greater
    Accuracy (TA430, TA440)Ā¹&Ā²: Ā±3% of reading or Ā±0.015 m/s (Ā±3 ft/min), whichever is greater
    Resolution: 0.01 m/s (1 ft/min)
    Duct Size (TA430, TA440)
    Dimensions: 1 to 635 cm in increments of 0.1 cm (1 to 250 inches in increments of 0.1 in.)
    Volumetric Flow Rate (TA430, TA440)
    Range: Actual range is a function of velocity, and duct size
    Temperature
    Range (TA410, TA430): -18 to 93Ā°C (0 to 200Ā°F)
    Range (TA440): -10 to 60Ā°C (14 to 140Ā°F)
    AccuracyĀ³: Ā±0.3Ā°C (Ā±0.5Ā°F)
    Resolution: 0.1Ā°C (0.1Ā°F)
    Relative Humidity (TA440 only)
    Range: 5 to 95% RH
    Accuracyā“: Ā±3% RH
    Resolution: 0.1% RH
    Wet Bulb Temperature (TA440 only)
    Range: 5 to 60Ā°C (40 to 140Ā°F)
    Resolution: 0.1Ā°C (0.1Ā°F)
    Dew Point (TA440 only)
    Range: -15 to 49Ā°C (5 to 120Ā°F)
    Resolution: 0.1Ā°C (0.1Ā°F)
    Instrument Temperature Range
    Operating (Electronics): 5 to 45Ā°C (40 to 113Ā°F)
    Model TA410, TA430: -18 to 93Ā°C (0 to 200Ā°F)
    Operating (Probe)
    Model TA440: -10 to 60Ā°C (14 to 140Ā°F)
    Operating (Probe)
    Storage: -20 to 60Ā°C (-4 to 140Ā°F)
    Data Storage Capabilities (TA430, TA440)
    Range: 12,700+ samples and 100 test IDs
    Logging Interval (TA430, TA440)
    1 second to 1 hour
    External Meter Dimensions
    8.4 cm x 17.8 cm x 4.4 cm (3.3 in. x 7.0 in. x 1.8 in.)
    Meter Weight with Batteries
    0.27 kg (0.6 lbs.)
    Meter Probe Dimensions
    Probe Length: 101.6 cm (40 in.)
    Probe Diameter: of Tip 7.0 mm (0.28 in.)
    Probe Diameter: of Base 13.0 mm (0.51 in.)
    Articulating Probe Dimensions
    Articulating Section 19.7 cm (7.8 in.)
    Length
    Diameter of 9.5 mm (0.38 in.)
    Articulating Knuckle
    Power Requirements
    Four AA-size batteries or AC adapter"