TSI Airflow Instruments : TA410 – Velocity Meter

RM4,400.00


Digital air velocity meter perfect for troubleshooting HVAC systems, plant maintenance and conducting commissioning work.

Download PDF

Availability: in stock

Items are currently out of stock. Will ship in 12-14 weeks.

CompareCompare

PRODUCT DETAILS

The Airflow™ Instruments Velocity Meter TA410 is a solid choice for a digital air velocity meter, without compromising accuracy and precision. It is perfect for troubleshooting HVAC systems, plant maintenance and conducting commissioning work.

FEATURES AND BENEFITS

  • Velocity Range is 0-20 m/s
  • Temperature range is 0 to 200°F (-18 to 93°C)
  • Accurate air velocity measurement
  • Integrated probe attachment
  • Large, easy to read display
  • Press button to hold reading
  • Calibration certificate included

There are no reviews yet.

Be the first to review “TSI Airflow Instruments : TA410 – Velocity Meter”

    Ask a question about this product

    Questions and answers of the customers

    There are no questions yet, be the first to ask something for this product.

    Velocity
    Range (TA410): 0 to 20 m/s (0 to 4,000 ft/min)
    Range (TA430, TA440): 0 to 30 m/s (0 to 6,000 ft/min)
    Accuracy (TA410)¹&²: ±5% of reading or ±0.025 m/s (±5 ft/min), whichever is greater
    Accuracy (TA430, TA440)¹&²: ±3% of reading or ±0.015 m/s (±3 ft/min), whichever is greater
    Resolution: 0.01 m/s (1 ft/min)
    Duct Size (TA430, TA440)
    Dimensions: 1 to 635 cm in increments of 0.1 cm (1 to 250 inches in increments of 0.1 in.)
    Volumetric Flow Rate (TA430, TA440)
    Range: Actual range is a function of velocity, and duct size
    Temperature
    Range (TA410, TA430): -18 to 93°C (0 to 200°F)
    Range (TA440): -10 to 60°C (14 to 140°F)
    Accuracy³: ±0.3°C (±0.5°F)
    Resolution: 0.1°C (0.1°F)
    Relative Humidity (TA440 only)
    Range: 5 to 95% RH
    Accuracy⁴: ±3% RH
    Resolution: 0.1% RH
    Wet Bulb Temperature (TA440 only)
    Range: 5 to 60°C (40 to 140°F)
    Resolution: 0.1°C (0.1°F)
    Dew Point (TA440 only)
    Range: -15 to 49°C (5 to 120°F)
    Resolution: 0.1°C (0.1°F)
    Instrument Temperature Range
    Operating (Electronics): 5 to 45°C (40 to 113°F)
    Model TA410, TA430: -18 to 93°C (0 to 200°F)
    Operating (Probe)
    Model TA440: -10 to 60°C (14 to 140°F)
    Operating (Probe)
    Storage: -20 to 60°C (-4 to 140°F)
    Data Storage Capabilities (TA430, TA440)
    Range: 12,700+ samples and 100 test IDs
    Logging Interval (TA430, TA440)
    1 second to 1 hour
    External Meter Dimensions
    8.4 cm x 17.8 cm x 4.4 cm (3.3 in. x 7.0 in. x 1.8 in.)
    Meter Weight with Batteries
    0.27 kg (0.6 lbs.)
    Meter Probe Dimensions
    Probe Length: 101.6 cm (40 in.)
    Probe Diameter: of Tip 7.0 mm (0.28 in.)
    Probe Diameter: of Base 13.0 mm (0.51 in.)
    Articulating Probe Dimensions
    Articulating Section 19.7 cm (7.8 in.)
    Length
    Diameter of 9.5 mm (0.38 in.)
    Articulating Knuckle
    Power Requirements
    Four AA-size batteries or AC adapter