Lascar EasyLog : EL-21CFR-2-LCD 21CFR Compatible Temperature, Humidity & Dew Point Data Logger with LCD Screen

RM832.10


▪ -35 to +80°C (-31 to +176°F) and 0 to 100%RH measurement range
▪ Stores over 16,000 readings for both temperature and humidity
▪ EasyLog 21CFR software available as a free download
▪ High contrast LCD, with two and a half digit temperature and
humidity display function
▪ Logging rates between 10 seconds and 12 hours
▪ Immediate, delayed and push-to-start logging
▪ User-programmable alarm thresholds for both temperature and humidity

Availability: in stock

Items are currently out of stock. Will ship in 12-14 weeks.

CompareCompare

This standalone data logger measures and stores over 16,000 temperature and humidity readings from -35 to +80°C (-31 to +176°F) and 0 to 100%RH range at a resolution of 0.5°C (1°F) and 0.5%RH.

The user can easily set up the logger and view downloaded data by plugging the data logger into a PC’s USB port and using the free
EasyLog 21CFR software. Data, including calculated dew point, can then be graphed, printed and exported to other applications for
detailed analysis. The encrypted data has full audit tracking to comply with the requirements of 21CFR Part 11.

The high contrast LCD can show a variety of temperature and humidity information. At the touch of a button, the user can cycle between the current temperature and humidity, along with the maximum and minimum stored values for temperature and humidity.

The data logger is supplied with a lithium metal battery, giving up to 2 years’ logging life. The logger is protected against ingress fromwater and dust to IP67 standard when the cap is fitted.

There are no reviews yet.

Be the first to review “Lascar EasyLog : EL-21CFR-2-LCD 21CFR Compatible Temperature, Humidity & Dew Point Data Logger with LCD Screen”

Questions and answers of the customers

There are no questions yet, be the first to ask something for this product.

SPECIFICATIONS
Temperature Measurement range: -35°C to 80°C (-31°F to 176°F)
Internal resolution: 0.5°C (1°F)
Accuracy (overall error)*: 0.55°C (1.04°F) typical (5 to 60°C)
Long term stability: <0.02°C (0.04°F) / year
Relative Humidity Measurement range: 0 to 100%RH
Internal resolution: 0.5%RH
Accuracy (overall error)*: 2.25%RH typical (20 to 80%RH)
Long term stability: <0.25%RH / year
Dew Point Accuracy (overall error)*: 1.7°C typical (-35 to 80°C, 40 to 100%RH)
Logging rate: User selectable between 10 seconds & 12 hours
Operating temperature range: -35 to +80°C (-31 to +176°F)
Battery life: 2 years (at 25°C and 1 minute logging rate, LCD on)
Readings: 16,382 temperature, 16,382 relative humidity
Dimensions: 126 x 25 x 22mm (4.96 x 0.98 x 0.86”)

Download Datasheet: EL-21CFR-2-LCD