TSI Airflow Instruments : HM685M Hydronic Manometer Metric


Hydronic Manometer Metric

Download PDF

Availability: in stock
CompareCompare

  • Provides for inputs for two temperature probes
  • Large backlit display for use in low light areas
  • Operates on four alkaline or NiMH rechargeable batteries
  • Reads in H2O, ft. H2O, psi, in.Hg, mmHg, mH2O, kPa or bar
  • Differential pressure range ±300 psi (±2068 kPa)
  • Gauge pressure range -20 to 300 psi (-138 to 2068 kPa)
  • Performs on-board universal flow and btu/hr calculations
  • Displays volumetric flow when a Cv (Kv) factor is programmed
  • Allows up to 100 Cv (Kv) factors to be entered
  • Calculates brake power, heat flow, Cv (Kv) factors, and impeller sizing
  • Stores up to 4,000 data points for recall or downloading via USB interface
  • Robust, splash-proof case
  • Meter weight with batteries is 2.65 lbs (1.20 kg)

There are no reviews yet.

Be the first to review “TSI Airflow Instruments : HM685M Hydronic Manometer Metric”

    Ask a question about this product

    Questions and answers of the customers

    There are no questions yet, be the first to ask something for this product.

    Pressure
    Differential Range -300 to 300 psi (-2,068 to 2,068 kPa)
    Gauge Range -20 to 300 psi (-138 to 2,068 kPa)
    (-40 to 610 in. Hg)
    Resolution (best) 0.001 psi (0.01 kPa)
    (0.01 in. Hg)
    Accuracy1 ±1% of reading plus .072 psi
    (0.5 kPa) (0.15 in. Hg)
    Units psi, in. H2O, ft H2O, kPa, mm Hg, in. Hg,
    m H2O, bar
    Pressure Connection ¼” 37• flare fitting, Male

    Temperature
    Operating (electronics) 40 to 113°F (5 to 45°C)
    Storage -4 to 140°F (-20 to 60°C)
    Liquid Media 32 to 180°F (0 to 82°C)
    Probe (immersion) -40 to 250°F (-40 to 121 °C)
    Resolution 0.1°F (0.1°C)
    Accuracy ±0.5% of reading +1.2°F (0.7 °C)
    Units °F, °C

    Flow 
    Range2 -22,712 to 22,271 m3/h, -99,999 to
    99,999 USGPM (-6,309 to 6,309 l/s)
    Resolution (best) 0.0001 USGPM (0.00001 l/s)
    Accuracy per pressure accuracy + valve
    deviation
    Units USGPM, UKGPM, m3/h, l/s, l/m

    Time Constant
    User selectable (1, 5, 10, 20, and 30 seconds)

    Statistics 
    min, max, average, sum up to 4,000 readings

    Data Storage 
    4,000 combined readings, 100 Test IDs

    Logging Interval 
    User selectable (1 to 3,600 seconds)

    External Meter Dimensions
    11.1 in. × 4.7 in. × 3.5 in. (28.2 cm × 11.9 cm × 8.8 cm)

    Meter Weight with Batteries
    2.65 lbs (1.20 kg)

    Power Requirements
    Four AA-size cells, or AC adapter