TSI Airflow Instruments : PH730 Micromanometer
Availability: | in stock |
Features and Benefits
+ Ergonomic design and ultra light weight for easy, one-person operation
+ Automatically senses and displays supply or return flows, saving time on the job
+ Back pressure compensation ensures accurate readings
+ Multiple hood sizes available for easy, cost effective use across multiple jobs
+ Detachable digital micromanometer offers flexibility to use in multiple applications
+ Includes Swirl X Flow Conditioner for use with twist or swirl type supply air diffusers
+ Compatible LogDat™ Mobile Remote Reader and Data Logger Software option simplifies documenting of results and emailing of reports
+ Capture hood stand eliminates the need for ladders (reaching diffusers up to 15 ft. (4.5 m)
Applications
+ Test and balance contractors
+ Commissioning agents
+ Facilities managers
+ Health and safety specialists
+ Ventilation system installers
There are no reviews yet.
Questions and answers of the customers
There are no questions yet, be the first to ask something for this product.
Velocity Range
Pitot probes: 0.125 to 78 m/s (25 to 15,500 ft/min)
Air flow probe: 0.125 to 12.5 m/s (25 to 2,500 ft/min)
Velocity matrix: 0.125 to 12.5 m/s (25 to 2,500 ft/min)
Accuracy: ±3% of reading ±0.04 m/s (±7 ft/min) at velocities >0.25 m/s (50 ft/min)
Units: m/s, ft/min
Resolution: 0.01 m/s (1 ft/min)
Pressure
Differential pressure: ±3735 Pa H2O (±15 in.); 37.5 kPa H2O (150 in.),maximum safe operating pressure
Absolute pressure: 356 to 1016 mm Hg (15 to 40 in. Hg)
Accuracy: ±2% of reading ±0.025 Pa H2O (±0.0001 in.) static and differential; ±2% of reading absolute
Units: in. H2O, in. Hg, Pa, hPa, kPa, mm Hg, cm Hg, mm H2O, cm H2O
Resolution: 0.001 Pa H2O (0.00001 in.) static and differential; 1 mm Hg (0.01 in. Hg) absolute
Volume
Range: 42 to 4250 m3/h (25 to 2,500 ft3/min) capture hood, supply and return
Accuracy: ±3% of reading ±12 m3/h (±7 ft3/min) at flows >85 m3/h (>50 ft3/min)
Units: m3/h, ft3/min, l/s, m3/min
Resolution: 1 m3/h (1 ft3/min)
RH
Range: 5 to 95% RH (temperature/RH probe)
Accuracy:±3% RH
Resolution: 0.1% RH
Temperature
Sensor in base: 4.4 to 60°C (40 to 140°F)
Temperature/RH probe: -10 to 60°C (14 to 140°F)
Accuracy: ±0.3°C (±0.5°F)
Units: °C, °F
Resolution: 0.1°C (0.1°F)
Instrument Temperature Range
Operating: 4.4 to 60°C (40 to 140°F)
Storage: -20 to 71°C (-4 to 160°F)
You may also like…
CH-Stand
RM4,100.00
.
RM1,700.00
Airflow Probe 800187
RM3,650.00
Model 966
RM6,900.00
Multipurpose electronic air balancing instrument primarily used for efficiently taking direct air volume readings at diffusers and grilles.
Temperature and Humidity Probe 800220
RM2,850.00
Velocity Matrix 801090
RM2,999.00
Related Products
The Alnor® AirGard® Model Air Flow Monitor 350-CEM goes a step beyond the Model 315-BSC. Its large LED and digital display of measured velocity…
Easy to use, hand held digital micrometer for fast, accurate and reliable pressure measurment. It can also calculate velocity.
RM3,890.00
3-in-1 instrument for measuring relative humidity, ambient temperature and the dew point.
RM2,365.00
Be the first to review “TSI Airflow Instruments : PH730 Micromanometer”
You must be logged in to post a review.